**This is a specialty item and will take 7-10 business days to ship** **No rush orders on this item**
Mel-8704R-MADD *Fantastic for Paranormal Investigations* Magnetic Anomaly Deviation Detector
The Mel-8704R-MADD was designed to detect minute fluctuations, oscillations, and disturbances in the Earth’s Natural Magnetic Field, while avoiding pulsations and resonances related to the earth’s atmosphere. Field strength and proximity changes are depicted using bi-color LED’s and audible tones. Operating Sequence To activate the MADD, pop open the tilt stand located at the rear of the Mel and depress the white button. The device will go through a quick diagnostic routine and flash the Red and Green LED’s. A single Yellow LED is used to indicate Power is ON. The Mel-8704R-MADD also performs an automatic Baseline at power ON, and defaults to sensitivity level of 1. There are a total of 5 sensitivity levels that can be easily activated depending on the individual environment and investigative circumstances. In sensitivity level 1, the user should be able to move about freely with the device in their hands. When small natural fluctuation occurs, the user can easily baseline the instrument to see if there are any other unusual disturbances present. This technique will allow you to analyze the situation better and make a more informed decision as to the cause of the signal detection. The user should remember that we are surrounded by waves of invisible energy and magnetic fields created by the earth’s rotation around its core. The device will easily detect these field changes, especially in the higher sensitivity ranges as you walk thru them. Red & Green LED’s The instrument can differentiate North and South Magnetic poles. Use any magnet to demonstrate the device sensitivity. The detection “sweet spot” is located at the top left side. Side Buttons – Baseline & Sensitivity The button labeled “Zero” is the baseline button. This button is used to baseline and Zero the device at any time. The other button labeled “Range” is for the sensitivity selection. As mentioned earlier, there are 5 sensitivity levels to choose from. When you turn the instrument ON, it automatically goes to level 1. You would then momentarily press the button to go to sensitivity 2, 3, 4, & 5 in sequence. Also notice that there are LED’s that will light up indicating what the level selection is. Level 2 = 2 LED’s, Level 3 = 3 LED’s, etc. When you use the higher sensitivity levels 4 & 5, the sound is mute on the first 2 LED’s after the power LED. There is a “trigger” that reactivates the sound on LED’s 3 – 5. Turning the Sound OFF / ON You can Mute the sound for the Green / Red or both LED’s. Red Mute – Hold the baseline button until all Red LED’s are ON and then release the button. Green Mute – Hold the baseline button until all Green LED’s are ON and then release the button. Red & Green Mute – Hold the baseline button until Red & Green are on together then release the button. Reset Back to Audible – Hold the baseline button until just the Yellow power light is ON and then release. Or, turn the power OFF / ON.